WhisperKOOL Quantum SS9000 Wine Cellar Cooling System
A high-capacity ducted split system for large cellars up to 3,000 cu. ft. — a powerful ducted evaporator paired with a remotely mounted, high-efficiency condenser up to 100 feet away.
Quantum SS9000 Key Features & Benefits
Built for Large Cellars
The Quantum SS9000 is a heavy-duty ducted split rated for cellars up to 3,000 cu. ft., moving up to 710 CFM through 14" supply and return ducts for even cooling across big rooms.
220V High-Efficiency Condenser
The 220V high-efficiency condenser holds a 55°F cellar even in demanding mechanical rooms, with an engineered ambient operating range of -20°F to 120°F.
Fully Ducted, Concealed Design
The evaporator installs up to 25 duct feet from the cellar and is ducted in, so no equipment is visible in your wine room.
Precise Digital Control
An advanced digital display (50-ft cable) works with a liquid-temperature-measuring bottle probe, so the thermostat reads the true temperature of your wine rather than the air.
Condenser Choice
Available with the 220V Standard H.E. condenser or a 220V Copeland condenser — select the option that fits your installation at checkout.
Technical Specifications
| Specification | Details |
|---|---|
| Max Cellar Size | Up to 3,000 cu. ft. (fully insulated cellar with a proper vapor barrier) |
| Cooling Capacity | Approx. 10,145 BTU/h sensible / 10,786 BTU/h total at 85°F condenser air intake (220V H.E.); up to 11,316 BTU/h total at 60°F |
| Ambient Operating Range | Engineered to perform in ambient temperatures from -20°F to 120°F (220V H.E. condenser) |
| Refrigerant | R-134a / R-513a |
| Evaporator | 29.5"L x 30.9"W x 19.8"H · 590–710 CFM · 120V, 15-amp dedicated circuit · 9.2 running amps · 96 lbs |
| Condenser – 220V Standard H.E. | 31.18"L x 10.75"W x 21.18"H · 210–230V, 15-amp dedicated circuit · 1.0 HP · FLA 4.89 · 64 lbs |
| Condenser – 220V Copeland | 24"L x 18.98"W x 16.16"H · 210–230V · 3.76 HP (LRA 35 / RLA 6.5) · 75 lbs |
| Line Set (not included) | Liquid line 3/8" OD; suction line 5/8" OD under 50 ft, 3/4" OD over 50 ft (H.E.) |
| Duct Size | 14" supply & 14" return (up to 25 ft each) |
| Drain Line | 3/4" female to base (CPVC/PVC) |
| Installation Distances | Evaporator up to 25 duct ft from the cellar; condenser up to 100 line ft from the evaporator |
| Thermostat | Advanced digital display (50-ft cable) with liquid-temperature-measuring bottle probe |
| Sound Level | Condenser approx. 48 dBA (220V H.E.) |
| Condenser Options | 220V Standard H.E. or 220V Copeland — select at checkout |
Where It Fits in the Range
The Quantum SS9000 is the entry point to the high-capacity Quantum series, rated for cellars up to 3,000 cu. ft. For larger rooms, step up to the Quantum SS12000 (up to 4,000 cu. ft.) or the twin-evaporator Quantum SS18000 and SS24000. Always confirm sizing with a heat-load calculation before ordering.
A Note on Sizing
The cellar-size rating assumes a fully insulated room with a complete vapor barrier. Design factors such as glass walls, stone or concrete, high ambient temperatures, frequent door openings, or in-cellar lighting can increase the cooling load. When in doubt, choose the next capacity up — an undersized unit can run continuously, fail to reach temperature, and is not covered under warranty. We're happy to help you run the numbers.
Installation & Setup
Professional installation required: WhisperKOOL split systems must be installed by a qualified, licensed HVAC/R technician. Installation by anyone else will void the warranty.
Pre-Installation Requirements
- Fully insulated cellar with a complete vapor barrier
- Evaporator: dedicated 120V, 15-amp circuit
- Condenser: dedicated 220V, 15-amp circuit
- 14" supply / 14" return duct runs planned (up to 25 ft each)
- Line set sized per run length (not included)
Placement & Distances
- Evaporator ducted up to 25 duct ft from the cellar
- Condenser up to 100 line ft from the evaporator
- Condenser can sit in a mechanical room, basement, garage, or rooftop
- Provide clear airflow around the condenser
- Route a 3/4" drain line from the evaporator base
Cellar Design Best Practices
- Maintain consistent insulation and seal all air leaks
- Install a properly weatherstripped cellar door
- Complete the vapor barrier on the warm side of the insulation
- Plan duct routing for even coverage of a large room
Maintenance
- Keep condenser coils clean and clear of debris
- Check the digital controller and bottle probe periodically
- Inspect the drain line for free flow
- Schedule an annual professional inspection
Product Documentation & Resources
Documentation & Resources
Warranty Coverage
Help & Support
Frequently Asked Questions
Manuals & documentation: Find your owner's manual — select the version matching your unit's voltage/condenser type and purchase date.
Payment & Security
Payment methods
Your payment information is processed securely. We do not store credit card details nor have access to your credit card information.